Application of a novel gastro-laryngeal mask in upper gastrointestinal endoscopy surgery: A pilot randomized clinical trial
Authors' conclusion
This study showed that the back-open JEA can not only provide a safe and effective airway guarantee for patients but also provide convenience for gastroenterologists to carry out endoscopic operations.
Study context
- Population
- Patients undergoing upper gastrointestinal endoscopy surgery under GA1,401 screened
- Participants
- 1,266 patients
- Comparison
- Jcerity Endoscoper™ Airway vs endotracheal tube
- Jcerity Endoscoper™ Airway (JEA)n = 633
- Endotracheal tube (ET)n = 633reference
Methodological detailspilot, single-centre, First Affiliated Hospital of Zhengzhou University, June 2021 to October 2023
- Pilot
- Single-centre
- First Affiliated Hospital of Zhengzhou University, June 2021 to October 2023
Primary result
As reported in the abstract
- Significantly shorter insertion time with JEA vs ET
- Less cardiovascular response during insertion with JEA vs ET
Further findings
- Endoscopist satisfaction with JEA
- 99.4%
Time to extubation and PACU residence time
- Shorter with JEA than ET
Safety
Pharyngodynia
- Lower incidence with JEA than ET