Cardiac arrest & resuscitation
Community First Responder Activation Reduces the Negative Impact of AED Distance on Bystander Defibrillation After Out-of-Hospital Cardiac Arrest
Main finding · Probability of bystander defibrillation (TMLE)Result — go to the resultPercentage-point difference 6.1 percentage points 95% CI 4.5–7.8Authors' conclusion
HeartRunner activation attenuated the decline in bystander defibrillation with increasing AED distance following OHCA, without a corresponding distance interaction for 30-day survival. Overall, TMLE supported higher bystander defibrillation and suggested a modest increase in 30-day survival with HeartRunner activation.
Study context
- Population
- Patients with out-of-hospital cardiac arrest (OHCA) eligible for HeartRunner activation in Denmark during 2017–2021
- Participants
- 5,753 OHCAs
- Exposure
- HeartRunner activation versus without HeartRunner activation, in relation to the distance to the nearest accessible AED
- Outcome
- Probability of bystander defibrillation (TMLE)
Methodological detailsmultivariable logistic regression with interaction terms, targeted maximum likelihood estimation (TMLE)
- Multivariable logistic regression with interaction terms
- Targeted maximum likelihood estimation (TMLE)
Main finding
Probability of bystander defibrillation (TMLE)
Percentage-point difference
6.1 percentage points
95% CI 4.5–7.8
P < 0.001
As reported in the abstract
Observational data: associations, not effects.
Further findings
Predicted bystander defibrillation at Q1 (389 m)
Predicted bystander defibrillation at median (717 m)
Predicted bystander defibrillation at Q3 (1,183 m)
| Outcome | Percentage-point difference (percentage points) (95% CI) | P value | |
|---|---|---|---|
| 30-day survival (TMLE) · increase with HeartRunner activation | 1.8 (0.1–3.6) | P = 0.038 | |
| −2024Difference, percentage points (linear scale) |
Bystander defibrillation across AED distances
- HeartRunner activation was associated with higher bystander defibrillation across AED distances
- P-interaction = 0.004
30-day survival, interaction with AED distance
- No interaction for 30-day survival
- P-interaction = 0.054
Cohort characteristics
- Median age
- 74 years
- Male
- 64%
- In private locations
- 78%
- HeartRunner activation
- 41%
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →