Airway management

Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation: A prospective randomised controlled trial

Eur J AnaesthesiolPublished Randomised controlled trial

Primary result · Transient sinus pauseResult — go to the resultOdds ratio 5.73 95% CI 1.53–21.53

Authors' conclusion

The hyperangulated videolaryngoscope blade is associated with a higher incidence of transient sinus pause than the standard angle blade during tracheal intubation.

Study context

Population
Patients scheduled for GA, tertiary university hospitalincluded in final analysis
Participants
134 patients
Comparison
Hyperangulated vs Standard
Primary endpoint
Transient decrease in heart rate or transient sinus pause during tracheal intubation
Methodological detailsprospective, single-centre
  • Prospective
  • Single-centre

Primary result

Transient sinus pause

Odds ratio

5.73

95% CI 1.53–21.53

P = 0.010

By group

Hyperangulated vs Standard
OR 5.73 (95% CI 1.53–21.53); P = 0.010

As reported in the abstract

Further findings

Intubation conditions

Percentage of glottic opening score significantly higher in Hyperangulated
Backward, upward, and rightward pressure significantly less frequent in Hyperangulated
Direct epiglottis lifting significantly more frequent in Hyperangulated
Total time of blade in mouth significantly longer in Hyperangulated

Original publication

Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation: A prospective randomised controlled trial. Eur J Anaesthesiol. Published 13 February 2026. doi:10.1097/eja.0000000000002243

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.