Cardiac arrest & resuscitation

Longitudinal assessment of automated gray-white matter ratio for outcome prediction after cardiac arrest

Crit CarePublished Prospective cohort study

Authors' conclusion

Automated GWR is a useful predictor of outcome after cardiac arrest, with higher accuracy on delayed CT (> 24 h).

Study context

Population
Comatose patients after cardiac arrest admitted to three ICUs
Participants
123 patients · 3 ICUs
Exposure
GWR at <24 h, 24-96 h and 96-168 h after cardiac arrest, poor vs good outcome
Outcome
Prognostic accuracy (ROC AUC) of GWR for poor neurological outcome (CPC 3-5)
Follow-up
3 months
Methodological detailsmulticentre, serial CT at three predefined time windows, automated atlas-based GWR
  • Multicentre
  • Serial CT at three predefined time windows
  • Automated atlas-based GWR

Main finding

As reported in the abstract

Prognostic accuracy of GWR for poor outcome
GroupAUC
< 24 h0.72 (95% CI 0.62-0.81)
24-96 h0.78 (95% CI 0.69-0.86)
96-168 h0.81 (95% CI 0.72-0.88)

AUC

< 24 h0.72 (95% CI 0.62-0.81)
24-96 h0.78 (95% CI 0.69-0.86)
96-168 h0.81 (95% CI 0.72-0.88)
GWR consistently lower in poor vs good outcome across all time windows
P < 0.001

Observational data: associations, not effects.

Further findings

GWR trajectory

GWR declined after first 24 h in poor-outcome patients, stable in good-outcome patients

Adding longitudinal GWR change to prediction · 96-168 h

AUC increased from 0.81 to 0.83

Original publication

Longitudinal assessment of automated gray-white matter ratio for outcome prediction after cardiac arrest. Crit Care. Published 29 December 2025. doi:10.1186/s13054-025-05762-4

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.