Safety, quality & education

Smartphone applications for measuring noise in the intensive care unit: A feasibility study

J Crit CarePublished Feasibility study

Authors' conclusion

Smartphone apps and low-cost external microphones can be used reliably to measure the average noise level in the intensive care unit after acoustic calibration.

Study context

Population
Noise levels in an ICU
Comparison
Smartphone apps with low-cost external microphones vs sound level meter
Outcome
Average and maximum noise levels (WHO guidance) measured by apps vs sound level meter
Methodological detailslaboratory test, field test in ICU, acoustic calibration
  • Laboratory test
  • Field test in ICU
  • Acoustic calibration

Main finding

As reported in the abstract

Average noise level

Field test, best app–microphone combination: negligible difference in average noise level vs sound level meter

< 2 dB

Further findings

Maximum noise level

Significant differences between apps and sound level meter
−0.9 dB to −4.7 dB

Original publication

Smartphone applications for measuring noise in the intensive care unit: A feasibility study. J Crit Care. Published 25 September 2023. doi:10.1016/j.jcrc.2023.154435