Cardiac arrest & resuscitation
Standardisation facilitates reliable interpretation of end-tidal CO2 (ETCO2) during manual cardiopulmonary resuscitation
Authors' conclusion
Standardising ETCO2 eliminates effects of VR and CD variations during manual CPR and facilitates comparison of values and trends among and within patients.
Study context
- Population
- OHCA cases with manual cardiopulmonary resuscitation (CPR)of 1,036 cases
- Participants
- 287 cases
- Exposure
- Standardised ETCO2 vs measured ETCO2
- Outcome
- ETCO2 values and trends during resuscitation
Main finding
As reported in the abstract
Ventilation rate (VR) mostly lower than recommended, highly variable within and among patients
8.8 vpm
Compression depth (CD) mostly within guidelines, less varied
49.8 mm
ETs lower than ETm
7.3 mmHg
Observational data: associations, not effects.
Further findings
| Outcome | Values |
|---|---|
| ETs by sex | Females 22.4 mmHg · Males 25.6 mmHg |
| ETs by initial rhythm | Shockable 29.1 mmHg · Not shockable 22.7 mmHg |
| ETs by intubation type | Supraglottic 25.6 mmHg · Endotracheal 22.4 mmHg |
| ETs by ROSC achieved | ROSC 34.5 mmHg · No ROSC 20.1 mmHg |
| ETs trend before ROSC | Non-ROSC −0.3 mmHg/min · ROSC + 0.2 mmHg/min |
| ETs trend after ROSC | Sustained −0.7 mmHg/min · Rearrest −2.1 mmHg/min |
| Peak ETs | Sustained 53.0 mmHg · Rearrest 42.5 mmHg |
Original publication
Standardisation facilitates reliable interpretation of ETCO2 during manual cardiopulmonary resuscitation. Resuscitation. Published 31 May 2024. doi:10. 1016/ j. resuscitation. 2024. 110259