Safety, quality & education

System-Level Reduction in Anesthetic Greenhouse Gas Emissions: Central Nitrous Oxide Deactivation, Clinical Decision Support, and Secular Change in a Multicenter Interrupted Time-Series Study

Anesth AnalgPublished Multicentre observational interrupted time-series study

Authors' conclusion

Central N2O pipeline deactivation was associated with the largest reduction in the N2O-attributable hourly CO2e emission rate; the association with total emissions in the primary model was not statistically significant (P = .069). Concurrent secular declines in N2O and desflurane use contributed additionally, whereas the clinical decision support Advisory was associated with a modest but statistically significant reduction in FGF rate and total hourly CO2e emission rate.

Study context

Population
General anesthetic cases at 11 NYC Health + Hospitals facilities, April 1, 2022 – December 31, 2025of 158,881 screened cases analysed
Participants
148,762 cases
Exposure
Clinical decision support Advisory prompting fresh gas flow (FGF) reduction and central nitrous oxide (N2O) pipeline deactivation vs pre-intervention
Outcome
Hourly CO2e emission rate from N2O and volatile agents
Methodological detailscase-level data aggregated to monthly group-level observations
  • Case-level data aggregated to monthly group-level observations

Main finding

As reported in the abstract

Hourly CO2e emission rate

Step reduction in total hourly CO2e emission rate

0.78 kg CO2e·h-1

95% CI 0.24–1.32; P = 0.006

Advisory

Reduction in N2O-attributable hourly emission rate (complete deactivation, group level)

1.67 kg CO2e·h-1

95% CI 1.23–2.12; P < 0.001

N2O pipeline deactivation · association with total emissions in primary model not significant (P = .069)

System-level hourly CO2e emission rate decline over study period, per month
0.143 kg CO2e·h-1 (95% CI, 0.11-0.18; P < .001)

Observational data: associations, not effects.

Further findings

OutcomeStep reduction (L·min-1) (95% CI)P value
FGFAdvisory vs Phase 10.163 (0.11–0.21)P < 0.001
Baseline anesthetic gas use (Phase 1)
3.90 · median · L·min-1
Baseline anesthetic gas use (Phase 1) — N2O annualized CO2e impact equivalent to share of all volatile agents combined
77%

Central N2O pipeline losses at Bellevue

Centrally supplied N2O lost before reaching patients
94.6%
CO2e generated annually (approximately), metric tons
2136
Multiple of combined annual emissions from all clinically administered anesthetic gases across 11-hospital system
2.58

Original publication

System-Level Reduction in Anesthetic Greenhouse Gas Emissions: Central Nitrous Oxide Deactivation, Clinical Decision Support, and Secular Change in a Multicenter Interrupted Time-Series Study. Anesth Analg. Published 28 September 2026. doi:10.1213/ane.0000000000008319

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.