Obstetric anesthesia

Ultrasonography versus palpation for spinal anesthesia in obese parturients undergoing cesarean delivery: a randomized controlled trial

Reg Anesth Pain MedPublished Randomised controlled trial

Authors' conclusion

Preprocedural ultrasonography did not decrease the number of needle passes required to obtain free CSF flow or improve other outcomes compared with landmark palpation during spinal anesthesia performed by a single experienced anesthesiologist in obese parturients undergoing cesarean delivery.

Study context

Population
American Society of Anesthesiologists (ASA) II–III parturients with BMI ≥35 kg/m², full-term singleton pregnancy, elective cesarean delivery under spinal anaesthesia2 equal groups
Participants
280 participants
Comparison
Ultrasonography vs Palpation
Primary endpoint
Number of needle passes required to obtain free cerebrospinal fluid (CSF) flow
Methodological detailspatient- and outcome assessor-blinded, single operator, All ultrasound and spinal procedures by a single experienced anaesthesiologist
  • Patient- and outcome assessor-blinded
  • Single operator
  • All ultrasound and spinal procedures by a single experienced anaesthesiologist

Primary result

As reported in the abstract

Ultrasonography

3

median · IQR 1–7

Palpation

3

median · IQR 1–7

P = 0.62

Secondary outcomes

Skin punctures, first-pass and first-puncture success, procedure duration, patient satisfaction

No significant differences between the two groups

Original publication

Ultrasonography versus palpation for spinal anesthesia in obese parturients undergoing cesarean delivery: a randomized controlled trial. Reg Anesth Pain Med. Published 15 May 2023. doi:10.1136/rapm-2022-104272

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.