Airway management

A quantitative evaluation of aerosol generation during awake tracheal intubation

AnaesthesiaPublished Mechanistic study

Authors' conclusion

Awake tracheal intubation and nasendoscopy can generate high concentrations of respiratory aerosol.

Study context

Population
Healthy anaesthetic trainees undergoing awake tracheal intubation and nasendoscopy with topical lidocaine, no sedation
Comparison
Aerosol during awake tracheal intubation steps and nasendoscopy vs volitional coughing
  • Nasendoscopyn = 38
Outcome
Peak aerosol concentration (optical particle sizer, particles.l-1)
Methodological detailsultraclean operating theatre, healthy volunteers, no sedation
  • Ultraclean operating theatre
  • Healthy volunteers
  • No sedation

Main finding

As reported in the abstract

Peak aerosol concentration

Bronchoscope through vocal cords vs Coughing: P = 0.266 · Lidocaine spray coughs vs Coughing: P < 0.001

Nasendoscopies with peak aerosol greater than a volitional cough
5

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

A quantitative evaluation of aerosol generation during awake tracheal intubation. Anaesthesia. Published 29 January 2023. doi:10.1111/anae.15968