A quantitative evaluation of aerosol generation during awake tracheal intubation
Authors' conclusion
Awake tracheal intubation and nasendoscopy can generate high concentrations of respiratory aerosol.
Study context
- Population
- Healthy anaesthetic trainees undergoing awake tracheal intubation and nasendoscopy with topical lidocaine, no sedation
- Comparison
- Aerosol during awake tracheal intubation steps and nasendoscopy vs volitional coughing
- Nasendoscopyn = 38
- Outcome
- Peak aerosol concentration (optical particle sizer, particles.l-1)
Methodological detailsultraclean operating theatre, healthy volunteers, no sedation
- Ultraclean operating theatre
- Healthy volunteers
- No sedation
Main finding
As reported in the abstract
Peak aerosol concentration
Bronchoscope through vocal cords vs Coughing: P = 0.266 · Lidocaine spray coughs vs Coughing: P < 0.001
- Nasendoscopies with peak aerosol greater than a volitional cough
- 5
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.
Original publication
A quantitative evaluation of aerosol generation during awake tracheal intubation. Anaesthesia. Published 29 January 2023. doi:10. 1111/ anae. 15968