Anesthesia for Endoscopic Strip Craniectomy Repair: A Single‐Center Retrospective Cohort Study

Paediatr AnaesthPublished Retrospective cohort study

Authors' conclusion

We report a > 20% transfusion rate in our infant cohort mostly with metopic repairs.

Study context

Population
Infants undergoing endoscopic strip craniectomy for craniosynostosis, Great Ormond Street Hospital, UK, 2019–2024
Participants
111 infants
Exposure
Single suture repair vs Bilateral or multisuture repair
Outcome
Red cell transfusion
Methodological detailssingle-centre, observational
  • Single-centre
  • Observational

Main finding

As reported in the abstract

Overall red cell transfusion rate

1 in 5 children

Transfusion in metopic suture repair

18/67, 26%

Observational data: associations, not effects.

Further findings

OutcomeSingle suture repairBilateral or multisuture repair
Hb reduction, preop to postopMean, g/L26 (SD ±15 g/L)35 (SD ±15 g/L)
Preoperative Hb114 g/L (±11 g/L SD)118 g/L (±7.17 g/L SD)
Postoperative Hb87 g/L (±13 g/L SD)85.5 g/L (±14.29 g/L SD)
  • Surgical procedure time: All sutures 73 (SD ±23) min
  • Surgical procedure time: Multisuture 96 (SD ±15) min

Hospital discharge and HDU care

Discharged on Day 1 postoperatively
106 (95%)
No children required high dependency care

Safety

Complications

Inadvertent extubation on positioning
2
Laryngospasm
1
Minor transfusion reaction
1

Original publication

Anesthesia for Endoscopic Strip Craniectomy Repair: A Single‐Center Retrospective Cohort Study. Paediatr Anaesth. Published 7 July 2025. doi:10.1111/pan.70008

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.