Pediatric anesthesia & critical care
Atmospheric particulate matter and hypoxaemia in Korean children receiving general anaesthesia: A retrospective analysis
Main finding · Intra-operative hypoxaemiaResult — go to the resultAdjusted odds ratio 1.71 95% CI 1.04–2.83Authors' conclusion
The level of particulate matter on the day of surgery pose a risk of intra-operative hypoxaemia in children receiving general anaesthesia.
Study context
- Population
- Children aged 18 years or younger receiving GA, January 2019 to October 2020finally analysed
- Participants
- 13,175 children
- Exposure
- PM10 ≥81 vs <81 μg m −3 on the day of surgery
- ≥81 μg m −3n = 275
- <81 μg m −3n = 12,900reference
- Outcome
- Intra-operative hypoxaemia (SpO2 <90% for >1 min, manually verified using vital sign registry data at 2 s intervals)
Methodological detailssingle-centre
- Single-centre
Main finding
Intra-operative hypoxaemia
Adjusted odds ratio
1.71
95% CI 1.04–2.83
P = 0.035
Events by group
≥81 μg m −3 vs <81 μg m −3
aOR 1.71 (95% CI 1.04–2.83); P = 0.035
As reported in the abstract
Observational data: associations, not effects.
Further findings
Overall incidence of intra-operative hypoxaemia
- Patients with intra-operative hypoxaemia, all analysed
- 3.85% (489/13 175)
Original publication
Atmospheric particulate matter and hypoxaemia in Korean children receiving general anaesthesia: A retrospective analysis. Eur J Anaesthesiol. Published 11 June 2024. doi:10. 1097/ eja. 0000000000002027