Pediatric anesthesia & critical care

Oxygen reserve index versus conventional peripheral oxygen saturation for prevention of hypoxaemia: A randomised controlled trial

Eur J AnaesthesiolPublished Randomised controlled trial

Authors' conclusion

Additional monitoring of the oxygen reserve index, with a target value of greater than 0.2 during paediatric airway surgery, alongside peripheral oxygen saturation, did not reduce the incidence of SpO2 ≤ 90%.

Study context

Population
Paediatric patients aged 18 years or less scheduled for laryngeal microsurgery, tertiary care paediatric hospital88 analysed
Participants
44 vs 44
Comparison
Oxygen reserve index monitoring vs control
  • Oxygen reserve indexn = 44
  • Controln = 44reference
Primary endpoint
Incidence of SpO2 90% or less during surgery
Methodological detailsstratified by tracheostomy tube, single-centre
  • Stratified by tracheostomy tube
  • Single-centre

Primary result

As reported in the abstract

Relative risk

1.27

95% CI 0.94–1.72

P = 0.114

Events by treatment group

Oxygen reserve index vs Control
RR 1.27 (95% CI 0.94–1.72); P = 0.114

Further findings

OutcomeOxygen reserve indexControlDifference (95% CI)P value
SpO2 ≤ 90% events among 128 rescue interventions18 of 75 vs 42 of 53 events24%79.2%55.2% (38.5–67.2%)P < 0.001

Median

OutcomeOxygen reserve indexControlP value
Number of SpO2 ≤ 90% events per patientLess in oxygen reserve index group0 (maximum 3)0 (maximum 8)P = 0.031

Original publication

Oxygen reserve index versus conventional peripheral oxygen saturation for prevention of hypoxaemia: A randomised controlled trial. Eur J Anaesthesiol. Published 27 May 2024. doi:10.1097/eja.0000000000002018

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.