Obstetric anesthesia

Development and validation of a German version of Obstetric Quality of Recovery-10 (ObsQoR-10-German)

Int J Obstet AnesthPublished Validation study

Authors' conclusion

ObsQoR-10-German is a valid, reliable and clinically feasible patient reported outcome measure for assessing inpatient quality of recovery in German-speaking women after elective cesarean and vaginal delivery.

Study context

Population
German-speaking patients after spontaneous vaginal or elective cesarean delivery at two Austrian university hospitals (Innsbruck, Graz)retest subset n=54
Participants
200 patients
Comparison
Vaginal vs elective cesarean delivery
  • Vaginaln = 100
  • Cesareann = 100reference
Outcome
ObsQoR-10-German score
Follow-up
24 hours
Methodological detailstranslation and validation of a patient-reported outcome measure, multicentre, prospective observational
  • Translation and validation of a patient-reported outcome measure
  • Multicentre
  • Prospective observational

Performance

As reported in the abstract

Vaginal

82.7

± 13.0

Cesarean

70.0

± 16.5

P < 0.001

Correlation with EQ-5D-3L (ρ), P <0.001
−0.710
Correlation with GHVAS (ρ), P <0.001
0.640
Internal consistency, Cronbach's alpha (all patients)
0.814

Original publication

Development and validation of a German version of Obstetric Quality of Recovery-10 (ObsQoR-10-German). Int J Obstet Anesth. Published 14 November 2024. doi:10.1016/j.ijoa.2024.104292

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.