Development and validation of a German version of Obstetric Quality of Recovery-10 (ObsQoR-10-German)
Authors' conclusion
ObsQoR-10-German is a valid, reliable and clinically feasible patient reported outcome measure for assessing inpatient quality of recovery in German-speaking women after elective cesarean and vaginal delivery.
Study context
- Population
- German-speaking patients after spontaneous vaginal or elective cesarean delivery at two Austrian university hospitals (Innsbruck, Graz)retest subset n=54
- Participants
- 200 patients
- Comparison
- Vaginal vs elective cesarean delivery
- Vaginaln = 100
- Cesareann = 100reference
- Outcome
- ObsQoR-10-German score
- Follow-up
- 24 hours
Methodological detailstranslation and validation of a patient-reported outcome measure, multicentre, prospective observational
- Translation and validation of a patient-reported outcome measure
- Multicentre
- Prospective observational
Performance
As reported in the abstract
Vaginal
82.7
± 13.0
Cesarean
70.0
± 16.5
P < 0.001
- Correlation with EQ-5D-3L (ρ), P <0.001
- −0.710
- Correlation with GHVAS (ρ), P <0.001
- 0.640
- Internal consistency, Cronbach's alpha (all patients)
- 0.814
Original publication
Development and validation of a German version of Obstetric Quality of Recovery-10 (ObsQoR-10-German). Int J Obstet Anesth. Published 14 November 2024. doi:10. 1016/ j. ijoa. 2024. 104292
Composed by AI from the published abstract and checked against it. How Briefs are made →