ICU sedation, delirium & recovery

Evaluation of the sensory environment in a large tertiary ICU

Crit CarePublished Observational study

Authors' conclusion

This study corroborates other studies confirming that the lighting and acoustic environments in the study ICU were suboptimal, potentially contributing to adverse patient outcomes.

Study context

Population
Selected bedspaces representing different bedspace types in a large tertiary ICU
Participants
3 monitored bedspaces
Outcome
Lighting and acoustic environment
Methodological detailssensor-based monitoring, descriptive analysis
  • Sensor-based monitoring
  • Descriptive analysis

Main finding

As reported in the abstract

Average daytime light intensity in 2 of 3 bedspaces
not exceeding 300 Lux
Average sound levels in study bedspaces (single room noisier than 2 open-plan bedspaces)
63.75, 56.80, and 59.71 dBA
Multiple peak sound levels
> 80 dBA
Maximum sound level recorded
> 105 dBA
New monitor or ventilator alarm commencing in each bedspace
every 69 s
Alarms actioned
5%

Observational data: associations, not effects.

Original publication

Evaluation of the sensory environment in a large tertiary ICU. Crit Care. Published 27 November 2023. doi:10.1186/s13054-023-04744-8

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.