Cardiac arrest & resuscitation

Feasibility of computer-aided aortic occlusion catheter in non-traumatic cardiac arrest

ResuscitationPublished Single-arm feasibility study

Authors' conclusion

A computer-aided automated aortic occlusion catheter can be safely implanted with a high success rate with regards to procedure time during ongoing cardiopulmonary resuscitation in patients suffering from cardiac arrest of non-traumatic origin.

Study context

Population
Patients with non-traumatic in-hospital or out-of-hospital cardiac arrest
Participants
10 patients
Outcome
Successful balloon inflation within 10 min from first vessel puncture
Methodological details2 German tertiary care hospitals
  • 2 German tertiary care hospitals

Main finding

As reported in the abstract

Primary endpoint achieved
eight out of nine
Mean time from first vessel puncture to total aortic balloon occlusion
5.4 min (±2.5 min)

Further findings

Successful balloon implantation

Balloon successfully implanted
ten out of ten (100 %)

BP increase during resuscitation after 2 min of aortic occlusion (in 80 % of patients) · after two minutes of aortic occlusion

mmHg

SBP increase
24.6 (baseline mean: 44.1 mmHg)
DBP increase
7.3 (baseline mean: 23.4 mmHg)
Mean arterial BP increase
13.0 (baseline mean: 30.3 mmHg)

Safety

Primary composite safety endpoint

Composite safety endpoint evident (renal failure requiring renal replacement therapy)
1 patient

Original publication

Feasibility of computer-aided aortic occlusion catheter in non-traumatic cardiac arrest. Resuscitation. Published 12 November 2025. doi:10.1016/j.resuscitation.2025.110879

Composed by AI from the published abstract and checked against it. How Briefs are made →