High vs Low Positive End-expiratory Pressure (PEEP) in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial

ChestPublished Randomised crossover physiological study

Authors' conclusion

The impact of high PEEP on ΔPes and lung stress is interindividually variable according to different effects on the respiratory system and lung compliance resulting from alveolar overinflation.

Study context

Population
Moderate-to-severe ARDS on assisted ventilation with PaO2/FiO2 ≤ 200 mm Hg and inspiratory effort (ΔPes) ≥ 10 cm H2Ocrossover
Participants
16 participants
Comparison
PEEP 15 vs 5 cm H2O, each with PSV or PC-IMV
Primary endpoint
Inspiratory effort (ΔPes)
Methodological detailsrandomized sequence of four ventilator settings, esophageal manometry, electrical impedance tomography
  • Randomized sequence of four ventilator settings
  • Esophageal manometry
  • Electrical impedance tomography

Primary result

As reported in the abstract

ΔPes

High PEEP + PSV

20

median · IQR 15–24 · cm H2O

Low PEEP + PSV

15

median · IQR 13–23 · cm H2O

High PEEP + PC-IMV

20

median · IQR 18–23

Low PEEP + PC-IMV

19

median · IQR 17–25

High PEEP + PSV vs Low PEEP + PSV: P = 0.24 · High PEEP + PC-IMV vs Low PEEP + PC-IMV: P = 0.67

Further findings

Median

OutcomeHigh PEEP + PSVLow PEEP + PSVHigh PEEP + PC-IMVLow PEEP + PC-IMVP value
Dynamic strain in ventral lung areasHigh PEEP + PSV vs Low PEEP + PSV0.49 (IQR 0.37–0.83)0.96 (IQR 0.62–1.56)0.65 (IQR 0.42–1.31)1.14 (IQR 0.79–1.52)P = 0.003
Dynamic strain in ventral lung areasHigh PEEP + PC-IMV vs Low PEEP + PC-IMVP = 0.002
  • Dynamic strain in ventral lung areas: results consistent during synchronous and asynchronous assistance

Respiratory system and transpulmonary driving pressures, tidal volume, lung/chest wall mechanics, pendelluft

Not different between study phases

Correlation of PEEP-induced change in respiratory system compliance with change in ΔPes, respiratory system and transpulmonary driving pressure

ΔPes: r
−0.85
ΔPes: P
P < 0.001
Respiratory system driving pressure: r
−0.75
Respiratory system driving pressure: P
P < 0.001
Transpulmonary driving pressure: r
−0.80
Transpulmonary driving pressure: P
P < 0.001
  • High PEEP lowered or raised these according to whether it increased or decreased compliance

Dependence of compliance change on PEEP-induced alveolar overinflation

R
−0.66
P
P = 0.006
  • Compliance changes driven by lung component

Dynamic strain in ventral lung areas

High PEEP caused variable recruitment and systematic redistribution of tidal volume toward dorsal regions

Original publication

High vs Low PEEP in Patients With ARDS Exhibiting Intense Inspiratory Effort During Assisted Ventilation: A Randomized Crossover Trial. Chest. Published 29 January 2024. doi:10.1016/j.chest.2024.01.040

Composed by AI from the published abstract and checked against it. How Briefs are made →