Respiratory failure & ventilation

Individualized positive end-expiratory pressure (PEEP) guided by electrical impedance tomography (EIT) in patients undergoing general anesthesia: A systematic review and meta-analysis

J Clin AnesthPublished Systematic review and meta-analysis

Authors' conclusion

Our meta-analysis suggests potential benefits of EIT-guided individualized PEEP setting in improving intraoperative oxygenation and lung compliance in patients undergoing general anesthesia.

Study context

Population
Patients undergoing GA
Participants
272 patients · 5 studies
Comparison
EIT-guided PEEP vs Fixed PEEP or other titration
Outcome
Oxygenation index (OI), lung compliance and number of postoperative pulmonary complications (PPCs)
Methodological detailssensitivity analysis
  • Sensitivity analysis

Pooled result

As reported in the abstract

EIT-guided PEEP vs Fixed PEEP or other titrationOdds ratio (95% CI)P value
Intraoperative OI
95.73(49.10–142.37)
P < 0.0001
Lung compliance
7.69(5.55–9.83)
P < 0.00001
Postoperative PPCs
0.87(0.41–1.82)
P = 0.71

Further pooled results

OutcomeOR (95% CI)P value
Number of IV vasoactive drugs1.22 (0.68–2.21)P = 0.51
OutcomeOR (95% CI)P value
Intraoperative MAP2.07 (−1.00 to 5.13)P = 0.19

Original publication

Individualized PEEP guided by EIT in patients undergoing general anesthesia: A systematic review and meta-analysis. J Clin Anesth. Published 25 January 2024. doi:10.1016/j.jclinane.2024.111397

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.