Inter-lung asymmetrical airway closure cause insufflation delay between lungs in acute hypoxemic respiratory failure

Ann Intensive CarePublished Physiological observational study

Authors' conclusion

In asymmetrical airway closure, titrating PEEP can minimize inter-lung insufflation delay and can be monitored by EIT.

Study context

Population
Patients with acute hypoxemic respiratory failure and airway closure (22 with ARDS)22 with ARDS
Participants
23 patients
Exposure
Asymmetrical vs no asymmetrical airway closure
  • With asymmetryn = 9
Outcome
Relation between AOP asymmetry and inter-lung insufflation delay at different PEEP levels

Main finding

As reported in the abstract

Inter-lung inflation delay during low flow inflation

P < 0.0001

Delay correlated to the difference of airway opening pressure (AOP) between the 2 lungs, Spearman R2
0.800

Observational data: associations, not effects.

Further findings

Inter-lung insufflation delay during tidal ventilation

P = 0.019

Inter-lung inflation delay vs difference of AOP between the 2 lungs (correlation)

Spearman R2
0.800
  • p < 0.0001

AOP in patients with asymmetrical airway closure

AOP in the sicker lung
10 [6-13] cmH20
AOP in the healthier lung
5 [3-9, ] cmH20

PEEP set at the crossing point of a decremental Electrical Impedance Tomography (EIT)-based PEEP trial

Decreased the inter-lung insufflation delay

Insufflation delay during pressure support

Still measurable; reduced by increasing PEEP from 5 to 10 cmH2O in asymmetrical lung injury

Original publication

Inter-lung asymmetrical airway closure cause insufflation delay between lungs in acute hypoxemic respiratory failure. Ann Intensive Care. Published 23 October 2024. doi:10.1186/s13613-024-01379-y

Composed by AI from the published abstract and checked against it. How Briefs are made →