Safety, quality & education

Intraoperative use of processed electroencephalogram in a quaternary center: a quality improvement audit

J Clin Monit ComputPublished Quality improvement audit

Authors' conclusion

We identified a reasonable use of EEG monitoring during general anesthesia, unfortunately not reaching our target of 100%.

Study context

Population
Surgical cases under GA at 24 daily locations, Cleveland Clinic Abu Dhabi, 15 consecutive working days in March 2023, after an EEG educational program
Participants
379 surgical cases
Outcome
Use of processed EEG monitoring during GA
Methodological detailsprospective, single-centre
  • Prospective
  • Single-centre

Main finding

As reported in the abstract

Processed EEG monitoring use

Cases with processed EEG monitoring

233

61%

Observational data: associations, not effects.

Further findings

Processed EEG use by specialty

Cardiothoracic Surgery
100%
Interventional Cardiology
90%
Vascular Surgery
75%
Otorhinolaryngology
29%
Gastrointestinal Endoscopy
25%
Interventional Pulmonology
20%
Neuroradiology suite: no processed EEG monitor used in cases under GA