Study context

Population
Adults (ASA I–III) undergoing robotic-assisted laparoscopic prostatectomy (RALP) in steep Trendelenburg (30 degrees), Nuovo Ospedale di Prato, Italy, November 2024–May 2025
Participants
40 adults
Outcome
Phase-dependent changes in cerebral oxygenation (rSO₂, ΔO₂Hb, ΔHHb; NIRS) and ONSD, and their temporal correlation
Follow-up
T0 baseline, T1 45 min and T2 120 min after Trendelenburg, T3 vesicourethral anastomosis, T4 before extubation in neutral position
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Right optic nerve sheath diameter (ONSD), T0 (mean ± SD)
3.79 ± 0.36 mm
Right ONSD, T3 (mean ± SD)
4.59 ± 0.47 mm
Left ONSD, T0 (mean ± SD)
3.80 ± 0.42 mm
Left ONSD, T3 (mean ± SD)
4.73 ± 0.47 mm
Correlation ΔHHb–ONSD, right (Pearson r; p < 10⁻¹⁶)
0.63
Correlation ΔHHb–ONSD, left (Pearson r; p < 10⁻¹⁶)
0.63

Observational data: associations, not effects.

Original publication

NIRS monitoring during steep trendelenburg in robotic prostatectomy. J Clin Monit Comput. Published 26 May 2026. doi:10.1007/s10877-026-01443-x