Obstetric anesthesia

Ondansetron for the Prevention of Pruritus in Women Undergoing Cesarean Delivery With Intrathecal Opioid: A Systematic Review and Meta-Analysis

Anesth AnalgPublished Systematic review and meta-analysis of randomised trials

Pooled resultResult — go to the resultRelative risk 0.81 95% CI 0.71–0.92

Authors' conclusion

This systematic review has demonstrated a significant reduction in the incidence of pruritus following the use of ondansetron.

Study context

Population
Women undergoing cesarean delivery under spinal anesthesia with intrathecal opioid (morphine, fentanyl, sufentanil)
Participants
2,586 women · 23 RCTs
Comparison
Ondansetron vs placebo
  • Ondansetronn = 1,219
  • Placebon = 1,030reference
Outcome
Presence of pruritus
Methodological detailsrandom-effects model, trial sequential analysis, sensitivity and subgroup analyses, Overall Grading of Recommendations Assessment, Development, and Evaluation (GRADE) quality of evidence low
  • Random-effects model
  • Trial sequential analysis
  • Sensitivity and subgroup analyses
  • Overall GRADE quality of evidence low

Pooled result

As reported in the abstract

Relative risk

0.81

95% CI 0.71–0.92

Ondansetron vs Placebo
RR 0.81 (95% CI 0.71–0.92)

Further pooled results

Time to onset of pruritus

No significant difference in pruritus onset between the groups
17.54 minutes (MD; 95% CI, −2.18 to 37.26)
  • I 2 = 83%

Original publication

Ondansetron for the Prevention of Pruritus in Women Undergoing Cesarean Delivery With Intrathecal Opioid: A Systematic Review and Meta-Analysis. Anesth Analg. Published 11 May 2023. doi:10.1213/ane.0000000000006526

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.