Obstetric anesthesia

Optic nerve sheath diameter as a real-time biomarker for epidural blood patch efficacy after post-dural puncture headache: a preliminary report

J Clin Monit ComputPublished Prospective observational study

Authors' conclusion

These preliminary findings suggest that ONSD ultrasound may offer a feasible, noninvasive adjunct for assessing early EBP response in PDPH.

Study context

Population
Postpartum patients with post-dural puncture headache (PDPH) after epidural anesthesia undergoing epidural blood patch (EBP)
Participants
30 patients
Outcome
Correlation between change in ultrasound optic nerve sheath diameter (ONSD) (ΔONSD) and change in VAS pain score (ΔVAS) after EBP
Follow-up
Before (H0) and 2 h after (H2) EBP
Methodological detailssingle-center, preliminary report, bootstrap validation
  • Single-center
  • Preliminary report
  • Bootstrap validation

Main finding

As reported in the abstract

ΔONSD and its correlation with pain reduction · 2 h after EBP

Correlation of ΔONSD with pain reduction (r)

r = - 0.64, p < 0.001; bootstrap 95% CI: −0.81 to - 0.36

Observational data: associations, not effects.

Further findings

ROC analysis of ΔONSD for early improvement

AUC
0.96, 95% CI: 0.87-1.00
Sensitivity at ΔONSD ≥ 0.40 mm threshold
100%
Specificity at ΔONSD ≥ 0.40 mm threshold
83%

Original publication

Optic nerve sheath diameter as a real-time biomarker for epidural blood patch efficacy after post-dural puncture headache: a preliminary report. J Clin Monit Comput. Published 5 February 2026. doi:10.1007/s10877-025-01395-8

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.