Haemodynamics, fluids & transfusion

Optimal ROTEM FIBTEM Thresholds for the Identification of Hypofibrinogenemia in Cardiac Surgical Patients: An Analysis of the Influence of Increased Sensitivity on the Rate and Magnitude of False Positives

J Cardiothorac Vasc AnesthPublished Diagnostic accuracy study

Authors' conclusion

In this study, using an A5 with 90% sensitivity to detect Clauss fibrinogen <1.5 g/L (<10 mm) had an FP rate of 25%. However, most of the FPs (80%) were <2.0 g/L.

Study context

Population
Cardiac surgical patients, public and private cardiothoracic surgical centres
Participants
800 patients
Comparison
FIBTEM A5 threshold <10 mm for identifying hypofibrinogenemia
Outcome
Rate and magnitude of false-positive hypofibrinogenemia with an A5 threshold of sensitivity ≥0.9
Methodological detailsmulticentre, observational
  • Multicentre
  • Observational

Performance

As reported in the abstract

False positives at A5 <10 mm
Test or modelValueSensitivity
A5 <10 mm25%≥0.9

A5 <10 mm

Value25%
Sensitivity≥0.9
False positives (FPs) in the range 1.5 to 2.0 g/L
80%

Original publication

Optimal ROTEM FIBTEM Thresholds for the Identification of Hypofibrinogenemia in Cardiac Surgical Patients: An Analysis of the Influence of Increased Sensitivity on the Rate and Magnitude of False Positives. J Cardiothorac Vasc Anesth. Published 29 August 2026. doi:10.1053/j.jvca.2026.08.156

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.