Respiratory failure & ventilation

Personalized positive-end expiratory pressure using electrical impedance tomography in Acute Respiratory Distress Syndrome (ARDS) patients: a systematic review and meta-analysis

Ann Intensive CarePublished Systematic review and meta-analysis of randomised and observational studies

Authors' conclusion

EIT-guided PEEP titration improves oxygenation and respiratory system compliance in patients with ARDS, supporting its role as a physiology-based strategy for ventilatory personalization.

Study context

Population
Adults with ARDS
Participants
356 adults · 9 studies
Comparison
Electrical Impedance Tomography (EIT)-guided vs conventional positive end-expiratory pressure (PEEP) titration
Outcome
PaO2/FiO2 ratio and respiratory system compliance (Crs)
Methodological detailsrandom-effects meta-analysis, PRISMA 2020, MOOSE, GRADE
  • Random-effects meta-analysis
  • PRISMA 2020
  • MOOSE
  • GRADE

Pooled result

As reported in the abstract

MD

+ 60.81

95% CI 30.37–91.25

PaO2/FiO2 ratio; low heterogeneity

MD

+ 6.81 mL/cm H2O

95% CI 3.73–9.89

Respiratory system compliance

Further pooled results

Driving pressure (ΔP)

MD (cm H2O) (95% CI)
Between groups−0.78 (−1.63 to 0.07)

Mechanical power (MP)

MD (J/min) (95% CI)
Across groupsNon-significant difference−0.76 (−2.30 to 0.78)

Mortality

Risk ratio (95% CI)
Between groups0.88 (0.45–1.72)

Original publication

Personalized positive-end expiratory pressure using electrical impedance tomography in ARDS patients: a systematic review and meta-analysis. Ann Intensive Care. Published 16 March 2026. doi:10.1016/j.aicoj.2026.100049

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.