Pediatric anesthesia & critical care

Point-of-Care Lung Ultrasound to Evaluate Lung Isolation During One-Lung Ventilation in Children: A Blinded Observational Feasibility Study

Anesth AnalgPublished Diagnostic accuracy study

Authors' conclusion

Based on the initial results of our feasibility trial, lung ultrasound proved to be a fast and reliable method to verify single-lung ventilation in pediatric patients presenting for thoracic surgery with a high degree of diagnostic accuracy.

Study context

Population
Pediatric patients aged 0 to 20 years undergoing thoracic surgery with one-lung ventilation (OLV); lung separation confirmed by fiberoptic bronchoscopy (FOB), definitively by direct visualization of lung collapse
Participants
40 patients
Comparison
Lung ultrasound vs clinical auscultation to confirm OLV
Outcome
Diagnostic accuracy in confirming effective single-lung ventilation
Methodological detailsprospective, blinded, feasibility study
  • Prospective
  • Blinded
  • Feasibility study

Performance

As reported in the abstract

Diagnostic accuracy for confirming lung isolation
Test or modelValueAccuracy
Lung ultrasound95% (95% CI 82.7%–98.5%)95%
Auscultation68% (95% CI 51.5%–80.4%)68%

Value

Lung ultrasound95% (95% CI 82.7%–98.5%)
Auscultation68% (95% CI 51.5%–80.4%)

Accuracy

Lung ultrasound95%
Auscultation68%
  • Lung ultrasound vs Auscultation: P < 0.001 — McNemar test

Further findings

Time to perform assessment

Original publication

Point-of-Care Lung Ultrasound to Evaluate Lung Isolation During One-Lung Ventilation in Children: A Blinded Observational Feasibility Study. Anesth Analg. Published 15 November 2024. doi:10.1213/ane.0000000000007155

Composed by AI from the published abstract and checked against it. How Briefs are made →