Respiratory failure & ventilation

Pulmonary pulsatility quantified by electrical impedance tomography in severe acute respiratory distress syndrome patients undergoing extracorporeal membrane oxygenation support

Ann Intensive CarePublished Secondary analysis of a cohort study

Authors' conclusion

n severe ARDS patients on ECMO, pulsatility amplitude reflects stroke volume changes induced by positive intrathoracic pressures and mixed venous saturation targets. However, downstream flow obstruction appears to be the leading determinant in the dorsal lung and may be useful to monitor right heart loading in patients with ARDS.

Study context

Population
Severe acute respiratory distress syndrome (ARDS) patients on veno-venous extracorporeal membrane oxygenation (ECMO), protective ventilation16/20 analysable electrical impedance tomography (EIT)
Participants
20 patients
Comparison
ECMO blood flow adjusted to 3 SvO2 target ranges
Primary endpoint
Relationship between regional EIT pulsatility and pulmonary hemodynamics
Follow-up
30 min after adjusting ECMO blood flow
Methodological detailsphysiological study, reanalysis, randomised order of ECMO blood flow steps, mixed-effects modelling, EIT units calibrated to millilitres of tidal volume (ml*), PEEP 15[12-16] cmH2O, Vt 4 ± 1 ml/kg PBW
  • Physiological study
  • Reanalysis
  • Randomised order of ECMO blood flow steps
  • Mixed-effects modelling
  • EIT units calibrated to millilitres of tidal volume (ml*)
  • PEEP 15[12-16] cmH2O, Vt 4 ± 1 ml/kg PBW

Primary result

As reported in the abstract

Pulsatility amplitude vs hemodynamics (across blood flow steps)
Pulsatility amplitude directly related to stroke volume (SV), β (ml*/mL), p = 0.014
0.28 (0.06 - 0.5)
Pulsatility amplitude directly related to pulmonary artery pressure (PAPs), β (ml*/mmHg), p = 0.008
0.47 (0.14 - 0.81)
Pulsatility amplitude inversely related to PvO2, β (ml*/mmHg), p = 0.039
−0.41 (−0.79--0.03)
Concordance rate of pulsatility changes with SV changes
80%
Concordance rate of pulsatility changes with PAPs changes
83%

Further findings

OutcomeLow SvO2Intermediate SvO2High SvO2
Correlation of dorsal pulsatility with pulmonary artery pressureModerate to strong correlations
ρ0.720.590.81
pp = 0.001p = 0.017p < 0.001

Ventral lung pulsatility during inspiration

Decrease in ventral lung pulsatility during inspiration at each ECMO blood flow step (p < 0.01 for all steps)

Original publication

Pulmonary pulsatility quantified by electrical impedance tomography in severe acute respiratory distress syndrome patients undergoing extracorporeal membrane oxygenation support. Ann Intensive Care. Published 28 March 2026. doi:10.1016/j.aicoj.2026.100058

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.