Perioperative medicine & outcomes

Reliability of an all-in-one wearable sensor for continuous vital signs monitoring in high-risk patients: the NIGHTINGALE clinical validation study

J Clin Monit ComputPublished Method comparison study

Authors' conclusion

The CPC12S system showed high accuracy for measurements of HR. The accuracy of RR, SpO2 were slightly overestimated and core temperature underestimated, with LoA outside the predefined clinical acceptable range. The accuracy of BP was unacceptably low.

Study context

Population
High-risk surgical patients admitted to high-dependency wards, 4 European hospitals3,212 h of data analysed
Participants
70 patients
Exposure
Wearable CPC12S system vs ICU-grade monitoring
Outcome
Bias and 95% limits of agreement (LoA) for HR, RR, SpO2, BP and temperature
Methodological detailsobservational, multicentre
  • Observational
  • Multicentre

Main finding

As reported in the abstract

Bias (95% LoA), pooled analysis
HR bias (95% limits of agreement (LoA))
0.0 (−3.5 to 3.4)
RR bias (95% LoA)
1.5 (−3.7 to 7.5)
SpO2 bias (95% LoA)
0.4 (−3.1 to 4.0)
Blood pressure (BP) bias (LoA); BP overestimated
8.9 (−23.3 to 41.2)
Temperature bias (LoA); underestimated
−0.6 (−1.7 to 0.6)

Observational data: associations, not effects.

Further findings

Clinical accuracy (Clarke Error Grid): adequate treatment decisions

HR
99.2%
RR
92.0%

Original publication

Reliability of an all-in-one wearable sensor for continuous vital signs monitoring in high-risk patients: the NIGHTINGALE clinical validation study. J Clin Monit Comput. Published 18 March 2025. doi:10.1007/s10877-025-01279-x

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.