Hemodynamics, fluids & transfusion

Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review

J Clin Monit ComputPublished Systematic review

Authors' conclusion

Most individual studies have suggested that SVV and PPV are sufficiently reliable for predicting fluid responsiveness during laparoscopic surgery. However, the limited number of patients, varied apparatus used to define fluid responsiveness, diverse definitions of fluid responsiveness, and different fluids used to perform fluid challenges in the included studies render firm conclusions about SVV's and PPV's reliability impossible.

Study context

Population
Patients undergoing laparoscopic surgery7 studies
Comparison
Stroke volume variation (SVV) vs PPV
Outcome
Reliability of SVV and PPV in predicting fluid responsiveness (AUROC)

Pooled result

As reported in the abstract

AUROC for predicting fluid responsiveness
  • SVV AUROC less than 0.8 in 2 studies
  • SVV AUROC > 0.8 in 5 studies
  • Pooled AUROC for SVV and PPV more than 0.8, high heterogeneity between studies
  • High heterogeneities between the included studies

Original publication

Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review. J Clin Monit Comput. Published 18 November 2022. doi:10.1007/s10877-022-00939-6