Neuroanesthesia & neurocritical care

Time to maximum pupil constriction is variable in neurocritical care patients

J Clin Monit ComputPublished Cross-sectional study

Authors' conclusion

The tMC does not occur at a fixed point in time.

Study context

Population
Neuroscience ICU patients with normal pupillary light reflex values
Participants
50 patients
Outcome
Time to maximum pupil constriction (tMC) by quantitative pupillometry, within (left vs right eye) and between patients

Main finding

As reported in the abstract

tMC, all patients

Mean (SD) to maximum constriction (tMC), normally distributed across all patients

0.97 (0.17) s

Range of tMC

0.46 s to 1.35 s

Within-subject mean (SD) difference, left vs right eye

0.13 (0.12)s

Within-subject difference range

0.0 to 0.56 s

Observational data: associations, not effects.

Further findings

tMC, left vs right pupil · similar

P = 0.546

Original publication

Time to maximum pupil constriction is variable in neurocritical care patients. J Clin Monit Comput. Published 18 October 2024. doi:10.1007/s10877-024-01234-2