Airway management

Tracheal tube introducer‐associated airway trauma: a systematic review

AnaesthesiaPublished Systematic review

Authors' conclusion

Stylets might be associated with an increased risk of airway trauma compared with other devices or when no stylet was used, though the quality of evidence is modest.

Study context

Population
Patients undergoing tracheal intubation with a tracheal tube introducer
Participants
10,797 patients · 16 RCTs · 5 observational studies
Comparison
Tracheal tube introducers and airway trauma
Outcome
Tracheal tube introducer-associated airway trauma
Methodological detailsPubMed, EMBASE and CINAHL searched; 2 authors independently assessed results, extracted data and assessed risk of bias
  • PubMed, EMBASE and CINAHL searched; 2 authors independently assessed results, extracted data and assessed risk of bias

Pooled result

As reported in the abstract

Pooled incidence of airway trauma

Original publication

Tracheal tube introducer‐associated airway trauma: a systematic review. Anaesthesia. Published 28 July 2024. doi:10.1111/anae.16379

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.