Sepsis & infection

VExUS-ED: Early venous congestion is associated with clinical fluid overload in patients with sepsis

J Crit CarePublished Prospective cohort study

Authors' conclusion

In patients with suspected sepsis, mild venous congestion was independently associated with clinical fluid overload within 72 h.

Study context

Population
Adults with suspected sepsis requiring initial fluid resuscitation in the emergency department (ED), Venous Excess Ultrasound (VExUS) within 3 h of ED admission
Participants
103 adults
Exposure
VExUS>0 vs VExUS grade 0 at ED admission
Outcome
Clinical fluid overload (positive fluid balance plus ≥10% weight gain, pulmonary edema on imaging, or loop diuretic use)
Follow-up
72 h
Methodological detailssingle-centre data-biobank (Acutelines)
  • Single-centre data-biobank (Acutelines)

Main finding

As reported in the abstract

Clinical fluid overload within 72 h
Baseline
Adjusted odds ratio (95% CI)P value
VExUS>0 vs VExUS grade 0
3.66(1.23–11.55)
P = 0.022
Abnormal hepatic venous Doppler flow
4.20(1.21–16.38)
P = 0.028
Clinical fluid overload, overall
34 (33%)

Observational data: associations, not effects.

Further findings

VExUS grade at ED admission

Grade 0
75%
Grade 1
22%
Grade ≥ 2
3%

Next-day fluid overload (repeated-measures analyses)

VExUS>0 and abnormal intrarenal venous Doppler flow associated with next-day fluid overload

Original publication

VExUS-ED: Early venous congestion is associated with clinical fluid overload in patients with sepsis. J Crit Care. Published 13 March 2026. doi:10.1016/j.jcrc.2026.155488

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.