Perioperative medicine & outcomes

Wireless continuous single‐lead ST‐segment monitoring to detect new‐onset myocardial injury at the general ward—An exploratory subanalysis

Acta Anaesthesiol ScandPublished Diagnostic accuracy study

Authors' conclusion

In conclusion, wireless single-lead ECG monitoring with corrected ST thresholds detected patients developing myocardial injury with specificities >90% and sensitivities <20%

Study context

Population
Patients after major abdominal cancer surgery or with acute exacerbation of COPD at the general wardincluded for analysis
Participants
528 patients
Comparison
ST-threshold ≥10 min vs ST-threshold ≥20 min
Outcome
Myocardial injury (hsTnT 20-64 ng/L with absolute change ≥5 ng/L, or hsTnT ≥ 65 ng/L); detection by ST-deviation thresholds
Follow-up
Up to 4 days
Methodological detailsexploratory subanalysis, Wireless single-lead electrocardiogram (ECG) patch for up to 4 days with daily troponin measurements
  • Exploratory subanalysis
  • Wireless single-lead ECG patch for up to 4 days with daily troponin measurements

Performance

As reported in the abstract

Detection of myocardial injury
Test or modelSpecificitySensitivityOR
ST-threshold ≥10 min91%17%2.0 (95% CI: 1.1; 3.9)
ST-threshold ≥20 min94%13%2.4 (95% CI: 1.1; 5.1)

Specificity

ST-threshold ≥10 min91%
ST-threshold ≥20 min94%

Sensitivity

ST-threshold ≥10 min17%
ST-threshold ≥20 min13%

OR

ST-threshold ≥10 min2.0 (95% CI: 1.1; 3.9)
ST-threshold ≥20 min2.4 (95% CI: 1.1; 5.1)
Patients with myocardial injury
15.5%

Original publication

Wireless continuous single‐lead ST‐segment monitoring to detect new‐onset myocardial injury at the general ward—An exploratory subanalysis. Acta Anaesthesiol Scand. Published 29 February 2024. doi:10.1111/aas.14391