Perioperative medicine & outcomes
Wireless continuous single‐lead ST‐segment monitoring to detect new‐onset myocardial injury at the general ward—An exploratory subanalysis
Authors' conclusion
In conclusion, wireless single-lead ECG monitoring with corrected ST thresholds detected patients developing myocardial injury with specificities >90% and sensitivities <20%
Study context
- Population
- Patients after major abdominal cancer surgery or with acute exacerbation of COPD at the general wardincluded for analysis
- Participants
- 528 patients
- Comparison
- ST-threshold ≥10 min vs ST-threshold ≥20 min
- Outcome
- Myocardial injury (hsTnT 20-64 ng/L with absolute change ≥5 ng/L, or hsTnT ≥ 65 ng/L); detection by ST-deviation thresholds
- Follow-up
- Up to 4 days
Methodological detailsexploratory subanalysis, Wireless single-lead electrocardiogram (ECG) patch for up to 4 days with daily troponin measurements
- Exploratory subanalysis
- Wireless single-lead ECG patch for up to 4 days with daily troponin measurements
Performance
As reported in the abstract
Detection of myocardial injury
| Test or model | Specificity | Sensitivity | OR |
|---|---|---|---|
| ST-threshold ≥10 min | 91% | 17% | 2.0 (95% CI: 1.1; 3.9) |
| ST-threshold ≥20 min | 94% | 13% | 2.4 (95% CI: 1.1; 5.1) |
Specificity
ST-threshold ≥10 min91%
ST-threshold ≥20 min94%
Sensitivity
ST-threshold ≥10 min17%
ST-threshold ≥20 min13%
OR
ST-threshold ≥10 min2.0 (95% CI: 1.1; 3.9)
ST-threshold ≥20 min2.4 (95% CI: 1.1; 5.1)
- Patients with myocardial injury
- 15.5%
Original publication
Wireless continuous single‐lead ST‐segment monitoring to detect new‐onset myocardial injury at the general ward—An exploratory subanalysis. Acta Anaesthesiol Scand. Published 29 February 2024. doi:10. 1111/ aas. 14391
Composed by AI from the published abstract and checked against it. How Briefs are made →