Respiratory failure & ventilation

Accuracy of Pulse Oximetry and Risk Factors Associated With Discrepancy From Arterial Oxygenation in Asian Patients in the ICU: An Observational Study

ChestPublished Retrospective cohort study

Authors' conclusion

Our results show that dissociation between Spo2 and Sao2 in Asian patients in the ICU was small; however, overestimation and underestimation were associated with increased mortality risk, particularly among patients with chronic hemodialysis or impaired peripheral perfusion.

Study context

Population
Adult patients admitted to an ICU at a tertiary care hospital in Japan, October 2013 through September 2021
Participants
10,698 patients
Outcome
Agreement between SpO2 and SaO2 (bias)
Methodological detailssingle-center, observational
  • Single-center
  • Observational

Main finding

As reported in the abstract

Mean bias between SpO2 and SaO2

Mean bias between SpO2 and SaO2

−1.2%

Largest discrepancies after ICU admission (hours)

24.7

Observational data: associations, not effects.

Further findings

Hidden hypoxemia

Hidden hypoxemia (SaO2 < 88%, SpO2 ≥ 88%)
0.8%
Serious hidden hypoxemia (SpO2 ≥ 92%)
0.6%

Factors associated with SpO2-SaO2 differences

Overestimation of SaO2 associated with high creatinine, particularly with chronic hemodialysis; underestimation associated with sepsis, mechanical ventilation and signs of impaired systemic perfusion

Mortality

U-shaped relation between SpO2-SaO2 differences and mortality (nonlinear association)

Original publication

Accuracy of Pulse Oximetry and Risk Factors Associated With Discrepancy From Arterial Oxygenation in Asian Patients in the ICU: An Observational Study. Chest. Published 18 March 2025. doi:10.1016/j.chest.2025.03.006

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.