Respiratory failure & ventilation

Assessment of Respiratory Mechanics and Inspiratory Effort During Spontaneous Breathing Trials to Predict Extubation Failure in High-Risk Patients

Am J Respir Crit Care MedPublished Prospective observational diagnostic study

Authors' conclusion

In high-risk patients, SBT-induced declines in respiratory system compliance and increases in inspiratory effort are associated with extubation failure.

Study context

Population
Patients at high risk of extubation failure who passed a 30-minute SBT on conventional parametersextubated
Participants
238 patients
Comparison
Success vs Failure
  • Failuren = 46
Outcome
SBT-induced changes in respiratory mechanics and inspiratory effort, and extubation failure
Methodological detailsmulticentre
  • Multicentre

Performance

As reported in the abstract

Reintubation within 72 hours (extubation failure)
46 (19%) of 238
Failure: normalized compliance declined during SBT, ml/cm H2O/kg
1.0 [0.8-1.2] to 0.7 [0.6-0.9]; P < 0.001
Failure: inspiratory effort increased during SBT, cm H2O
12 [10-15] to 18 [15-20]; P < 0.001
P0.1 increased in both groups, more markedly in reintubated patients, cm H2O
2 [1.5-2.4] to 3.2 [2.9-3.5]; P < 0.001
Normalized compliance reduction ≤ −0.2 ml/cm H2O/kg predicting extubation failure: AUC (sensitivity, specificity)
0.90 [0.84-0.93] (80%, 83%)
Inspiratory effort increase >2 cm H2O predicting extubation failure: AUC (sensitivity, specificity)
0.94 [0.90-0.97] (89%, 93%)

Further findings

OutcomeFailure
P0.1 during SBTmedian 2 to 3.2 (IQR 1.5-2.4 to 2.9-3.5) cm H2O
Normalized compliance during SBT, Failure
1.0 to 0.7 · median · IQR 0.8-1.2 to 0.6-0.9 · ml/cm H2O/kg
Inspiratory effort during SBT, Failure
12 to 18 · median · IQR 10-15 to 15-20 · cm H2O
  • Normalized compliance during SBT, Failure: P < 0.001
  • Inspiratory effort during SBT, Failure: P < 0.001
  • P0.1 during SBT: P < 0.001

Normalized compliance during SBT, Failure

Unchanged in success group

Inspiratory effort during SBT, Failure

Unchanged in success group

P0.1 during SBT

Increased in both groups, more markedly in reintubated

Vt and respiratory rate

No differences between groups at any time

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Assessment of Respiratory Mechanics and Inspiratory Effort During Spontaneous Breathing Trials to Predict Extubation Failure in High-Risk Patients. Am J Respir Crit Care Med. Published 1 December 2025. doi:10.1164/rccm.202503-0544oc

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.