Comparison of Blood Culture Contamination Rates Between Initial Central Venous Puncture and Catheter Hub Sampling
Authors' conclusion
Initial central venous blood culture sampling before CVC insertion is a simple approach that does not generate additional costs and may reduce contamination while preserving accurate pathogen detection
Study context
- Population
- Critically ill patients requiring CVC placement, 5 surgical ICUs of a tertiary care university hospital, November 2024 to July 2025
- Participants
- 228 paired samples
- Exposure
- Initial central venous puncture sampling vs CVC wire hub sampling
- Outcome
- Blood culture contamination
Methodological detailspaired sampling, multicentre (5 surgical ICUs)
- Paired sampling
- Multicentre (5 surgical ICUs)
Main finding
As reported in the abstract
Initial central venous sampling vs Catheter wire hub samplingAbsolute risk difference, percentage points (95% CI)
Blood culture contamination
−10.6(−25.6% to −5.4%)
Initial central venous sampling vs Catheter wire hub samplingEstimate (95% CI)P value
Blood culture contamination
RR 0.25(0.12–0.53)
Blood culture contamination
OR 0.22(0.10–0.49)
P < 0.001- Procedures to prevent one contamination
- NNT 10 (95% CI 6–18)
Observational data: associations, not effects.
Further findings
- Detection of true pathogens comparable between techniques
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.