Anesthetic drugs & techniques

Comparison of effects of remimazolam and propofol on mask ventilation during general anaesthesia induction: A randomised controlled trial

Anaesth Crit Care Pain MedPublished Randomised controlled trial

Authors' conclusion

Compared to propofol, remimazolam induction was associated with easier mask ventilation and more stable blood pressure after LOC, despite a longer time to achieve LOC.

Study context

Population
Adults scheduled for elective surgery under GA
Participants
76 adults
Comparison
Remimazolam vs propofol for GA induction
Primary endpoint
Mask ventilation difficulty (Warters scale)

Primary result

As reported in the abstract

Warters score

Remimazolam

0.0

interval 0.0–0.8

Propofol

1.0

interval 0.0–3.0

P = 0.002

Secondary outcomes

OutcomeOR (95% CI)P value
Mask ventilation difficulty requiring >1 airway device · during induction0.23 (0.08–0.68)P = 0.006
OutcomeP value
Mean BP immediately after LOCHigher in remimazolamP = 0.037
Time to LOCLonger in remimazolamP < 0.001

Safety

Hypotension after induction

Incidence comparable between groups

Original publication

Comparison of effects of remimazolam and propofol on mask ventilation during general anaesthesia induction: A randomised controlled trial. Anaesth Crit Care Pain Med. Published 20 November 2025. doi:10.1016/j.accpm.2025.101703

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.