Hemodynamics, fluids & transfusion

Detection of fluid responsiveness by changes of perfusion index and pleth-variability index during passive leg raising in spontaneously breathing post-surgical patients: a prospective interventional study

J Clin Monit ComputPublished Prospective interventional study

Authors' conclusion

In conclusion, PI could be a helpful non-invasive tool for predicting fluid responsiveness during a PLR test in spontaneously breathing patients, though its diagnostic accuracy appears to be moderate.

Study context

Population
Spontaneously breathing patients after major abdominal surgery in the ICU of Merano Hospital, Italyenrolled
Participants
47 participants
Exposure
Perfusion index (PI) and pleth variability index (PVI) changes during passive leg raising (PLR) in fluid responders vs non-responders
  • Respondersn = 23
Outcome
Prediction of fluid responsiveness (SV increase ≥ 10% during PLR) by PI and PVI
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Percentage change in PI from baseline to 60 s into PLR · 60 s

Responders

+ 41.2%

Non-responders

+ 11.3%

PI increase ≥ 23% predicting responders: sensitivity
70%
PI increase ≥ 23% predicting responders: specificity
75%
AUC (ROC)
0.74
Patients inside the grey zone
22 (47%)

Observational data: associations, not effects.

Original publication

Detection of fluid responsiveness by changes of perfusion index and pleth-variability index during passive leg raising in spontaneously breathing post-surgical patients: a prospective interventional study. J Clin Monit Comput. Published 7 April 2025. doi:10.1007/s10877-025-01292-0

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.