Respiratory failure & ventilation

Diaphragm physiological similarity index (DPSI): a de Novo speckle-tracking ultrasound metric for high-flow nasal cannula (HFNC) adjustment in acute respiratory failure

Crit CarePublished Prospective observational study

Authors' conclusion

DPSI is a feasible and reproducible speckle-tracking ultrasound metric that quantifies diaphragmatic motion patterns and distinguishes healthy from impaired contraction trajectories.

Study context

Population
Healthy volunteers, intensive care unit (ICU) patients and patients with acute respiratory failure on HFNC
Participants
103 volunteers
Exposure
Healthy volunteers vs ICU vs acute respiratory failure (ARF)
  • Healthy volunteersn = 45reference
  • ICUn = 38
  • ARFn = 20
Outcome
Reproducibility and physiological responsiveness of DPSI
Methodological detailsspeckle-tracking ultrasound, prespecified stepwise HFNC flow adjustment protocol
  • Speckle-tracking ultrasound
  • Prespecified stepwise HFNC flow adjustment protocol

Main finding

As reported in the abstract

Mean inspiratory velocity reproducibility (ICC)
0.87
Peak displacement reproducibility (ICC)
0.69
DPSI reproducibility (ICC)
0.75
DPSI association with ROX index (R²; p < 0.001)
0.62
DPSI association with peak diaphragmatic excursion (R²; p < 0.001)
0.60

Observational data: associations, not effects.

Original publication

Diaphragm physiological similarity index (DPSI): a de Novo speckle-tracking ultrasound metric for HFNC adjustment in acute respiratory failure. Crit Care. Published 26 February 2026. doi:10.1186/s13054-026-05899-w

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.