Respiratory failure & ventilation

Electrical impedance tomography-guided positive end-expiratory pressure titration in acute respiratory distress syndrome (ARDS): a systematic review and meta-analysis

Intensive Care MedPublished Systematic review and meta-analysis of randomised and non-randomised studies

Authors' conclusion

EIT facilitates real-time, individualized PEEP adjustments, improving respiratory system mechanics.

Study context

Population
ARDS patients; literature January 2012 to May 202313 studies (3 RCTs)
Participants
623 patients
Comparison
EIT-guided positive end-expiratory pressure (PEEP) titration vs conventional methods
Outcome
Respiratory mechanics and mechanical power
Methodological detailsrandom-effects models, sensitivity analysis
  • Random-effects models
  • Sensitivity analysis

Pooled result

As reported in the abstract

EIT-guided PEEP vs Conventional methodsMD (95% CI)
Lung compliance; n = 941 cases
4.33(2.94–5.71)

MD -

Mechanical power; n = 148
1.99 (95% CI - 3.51, - 0.47)
Driving pressure; n = 903
1.20 (95% CI - 2.33, - 0.07)

Further pooled results

OutcomeMD (95% CI)
Lung compliance, randomised trials vs non-randomised studies (sensitivity analysis)Trend towards improvement · sensitivity analysis2.43 (- 0.39 to 5.26)

Mortality

Reduction in mortality rate associated with modest improvements in compliance and driving pressure (3 studies, 259 patients), RR
0.64 (95% CI 0.45–0.91)
  • Three studies

Original publication

Electrical impedance tomography-guided positive end-expiratory pressure titration in ARDS: a systematic review and meta-analysis. Intensive Care Med. Published 21 March 2024. doi:10.1007/s00134-024-07362-2

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.