Pediatric anesthesia & critical care

Electroencephalographic Indices for Clinical Endpoints during Propofol Anesthesia in Infants: An Early-phase Propofol Biomarker-finding Study

AnesthesiologyPublished Prospective dose-response (biomarker-finding) study

Authors' conclusion

SEF95 can be a biomarker for propofol anesthesia depth in infants

Study context

Population
Infants (3 to 12 months) under propofol anesthesia44 evaluable
Participants
49 infants
Exposure
Pacifier vs Electrical stimulation vs Laryngoscopy
Outcome
SEF95 ranges (ED50 and ED90) for three clinical endpoints of anesthesia, and correlation between SEF95 and propofol plasma concentration at steady state
Methodological detailsearly-phase, Dixon's up-down method, centered isotonic regression, linear mixed-effect model
  • Early-phase
  • Dixon's up-down method
  • Centered isotonic regression
  • Linear mixed-effect model

Main finding

As reported in the abstract

SEF95 at which 50% and 90% of infants did not respond
GroupED50ED90
Pacifier21.419.3
Electrical stimulation12.610.4
Laryngoscopy8.55.2

ED50

Pacifier21.4
Electrical stimulation12.6
Laryngoscopy8.5

ED90

Pacifier19.3
Electrical stimulation10.4
Laryngoscopy5.2
Per 1-Hz spectral edge frequency (SEF95) increase, decrease in plasma propofol concentration
0.24 μg/ml (propofol 0.5 to 6 μg/ml; 95% CI 0.19 to 0.29; P < 0.001; marginal R2 = 0.55)

Observational data: associations, not effects.

Original publication

Electroencephalographic Indices for Clinical Endpoints during Propofol Anesthesia in Infants: An Early-phase Propofol Biomarker-finding Study. Anesthesiology. Published 8 May 2024. doi:10.1097/aln.0000000000005043

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.