Is quantitative pupillometry affected by ambient light? A prospective crossover study

J Clin Monit ComputPublished Prospective crossover study

Authors' conclusion

We corroborate previous findings that the level of ambient light affects QP parameters in critically ill patients.

Study context

Population
Adult patients requiring invasive ventilation, critical care setting
Participants
20 patients
Exposure
Pupillometry under bright vs dark ambient light conditions
Outcome
Neurological Pupil index (NPi) compared across conditions (DC1 vs BC, BC vs DC2, DC1 vs DC2)

Main finding

As reported in the abstract

NPi
  • Median Neurological Pupil index (NPi) significantly lower in BC vs DC1 in both eyes
  • NPi decreased by 0.6 or more (in 25% of participants)
  • Significant increase in median NPi of both eyes from BC to DC2
  • No significant difference between DC1 and DC2

Observational data: associations, not effects.

Further findings

Other quantitative pupillometry (QP) parameters

Differences in NPi driven by differences in most, but not all, QP parameters included in NPi