Neuroanaesthesia & neurocritical care

Low baseline transcranial motor evoked potential (Tc-MEP) amplitude is associated with false-positive alerts in spine surgery: a ROC-based analysis across spinal pathologies

J Clin Monit ComputPublished Retrospective cohort study

Authors' conclusion

Lower baseline Tc-MEP amplitudes were associated with FP alerts.

Study context

Population
High-risk spine surgery cases monitored with Tc-MEPs, 2018 to 20201,748 waveforms analysed
Participants
307 cases
Exposure
Baseline Tc-MEP amplitude in false-positive (FP) vs true-negative waveforms
  • FPn = 253
Outcome
Association of absolute baseline Tc-MEP amplitude with FP alerts; pathology-specific cutoff values
Methodological detailsROC analysis, waveform-level analysis
  • ROC analysis
  • Waveform-level analysis

Main finding

As reported in the abstract

Baseline Tc-MEP amplitude

Observational data: associations, not effects.

Further findings

FP alert incidence (waveforms)
14.5% · 253

FP alert incidence (waveforms)

FP alerts more frequent in lower-extremity recordings

Exploratory ROC-derived baseline-amplitude cutoffs for FP alerts, by pathology

Spinal cord tumor surgery: cutoff (µV)
122
Spinal cord tumor surgery: AUC
0.68
Spinal deformity surgery: cutoff (µV)
180
Spinal deformity surgery: AUC
0.56
OPLL surgery: cutoff (µV)
160
OPLL surgery: AUC
0.61
Pooled cohort: cutoff (µV)
170
Pooled cohort: AUC
0.61
  • Exploratory

Original publication

Low baseline Tc-MEP amplitude is associated with false-positive alerts in spine surgery: a ROC-based analysis across spinal pathologies. J Clin Monit Comput. Published 28 September 2026. doi:10.1007/s10877-026-01505-0

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.