Airway management

Lung aeration estimated by chest electrical impedance tomography and lung ultrasound during extubation

Ann Intensive CarePublished Prospective observational study

Authors' conclusion

Before extubation, a loss of lung aeration was observed in patients who developed extubation failure afterwards. After extubation, this loss of lung aeration persisted and was associated with regional lung ventilation heterogeneity.

Study context

Population
Patients at risk of extubation failure after a successful SBT
Participants
40 patients
Exposure
Extubation failure vs successful extubation
  • Extubation failuren = 12
Outcome
Lung aeration before extubation (H0)
Follow-up
Before extubation

Main finding

As reported in the abstract

Lung ultrasound score (LUS), extubation failure vs successful extubation

19 vs 10

p = 0.003

Surface available for ventilation, extubation failure vs successful extubation

352 vs 406 pixels

p = 0.042

Observational data: associations, not effects.

Further findings

EIT indices and LUS after extubation

GI index and LUS higher, surface available for ventilation lower in extubation failure
Regional ventilation delay (RVD) and center of ventilation (CoV) not different between groups

Original publication

Lung aeration estimated by chest electrical impedance tomography and lung ultrasound during extubation. Ann Intensive Care. Published 26 September 2023. doi:10.1186/s13613-023-01180-3

Composed by AI from the published abstract and checked against it. How Briefs are made →