In critically ill patients, an increasing BMI was associated with higher ventilator settings, increased airway pressures, and impaired gas exchange, resulting in hypoxia and hypercapnia.
Study context
- Population
- Critically ill patients receiving mechanical ventilation > 12 h in a Danish ICU (Metabolomics Cohort)of 577 in cohort
- Participants
- 242 patients
- Exposure
- Effect of body mass index (BMI) on ventilator settings, measurements and blood gases
- Outcome
- Ventilator settings, ventilator measurements and ventilation blood gas parameters at admission
- Follow-up
- Admission
Methodological detailssingle-centre
- Single-centre
Main finding
As reported in the abstract
Admission values per one-unit increase in BMI
Increase, cmH2O (95% CI)P value
PEEP
0.14([0.07, 0.2])
P < 0.01Peak inspiratory pressure
0.23([0.12, 0.34])
P < 0.01Mean pressure
0.18([0.1, 0.27])
P < 0.01Per one-unit increase in BMI, as printed
Increase, L/min (95% CI)P value
Minute volume
0.08([0.03, 0.13])
P < 0.01Per one-unit increase in BMI, as printed
- PaO2/FiO2 ratio
- decrease 0.38 (95% CI [−0.64, −0.13]); P < 0.01
Observational data: associations, not effects.
Further findings
| Outcome | Increase (cmH2O) (95% CI) | P value | |
|---|---|---|---|
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIPEEP · mixed-effects linear regression | 0.14 ([0.08, 0.2]) | P < 0.01 | |
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIPeak inspiratory pressure · mixed-effects linear regression | 0.23 ([0.13, 0.32]) | P < 0.01 | |
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIMean pressure · mixed-effects linear regression | 0.2 ([0.12, 0.27]) | P < 0.01 | |
| −0.200.20.4Difference, cmH2O (linear scale) |
| Outcome | Increase (L/min) (95% CI) | P value | |
|---|---|---|---|
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIMinute volume · mixed-effects linear regression | 0.09 ([0.05, 0.12]) | P < 0.01 | |
| −0.0500.050.10.15Difference, L/min (linear scale) |
| Outcome | Increase (mL/kg PBW) (95% CI) | P value | |
|---|---|---|---|
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMITidal volume/kg PBW · mixed-effects linear regression | 0.08 ([0.05, 0.1]) | P < 0.01 | |
| −0.0500.050.10.15Difference, mL/kg PBW (linear scale) |
| Outcome | Increase (kPa) (95% CI) | P value | |
|---|---|---|---|
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIPaCO2 · mixed-effects linear regression | 0.05 ([0.03, 0.07]) | P < 0.01 | |
| −0.0500.050.1Difference, kPa (linear scale) |
| Outcome | Decrease (kPa) (95% CI) | P value |
|---|---|---|
| Average change over first 5 days of mechanical ventilation per one-unit increase in BMIPaO2 · mixed-effects linear regression | 0.07 ([−0.12, −0.03]) | P < 0.01 |
Original publication
Mechanical Ventilation of the Critically Ill Obese Patient—A Retrospective Cohort Study. Acta Anaesthesiol Scand. Published 2 November 2025. doi:10. 1111/ aas. 70142
Composed by AI from the published abstract and checked against it. How Briefs are made →