Obstetric anesthesia

Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial

Int J Obstet AnesthPublished Randomised controlled trial

Primary resultResult — go to the resultMean difference −0.11 cm 95% CI −0.17 to −0.1

Authors' conclusion

Para-laryngeal pressure was non-inferior to CP in occluding the esophagus in parturients undergoing cesarean delivery under general anesthesia and furthermore, no significant deterioration in intubation parameters was seen.

Study context

Population
Parturients scheduled for elective cesarean delivery under GA
Participants
40 participants
Comparison
Para-laryngeal pressure vs cricoid pressure during RSI
  • CPn = 20reference
  • Para-laryngeal (PL)n = 20
Primary endpoint
Change in antero-posterior diameter of the esophagus, measured by sonography
Methodological detailsprospective, non-inferiority
  • Prospective
  • Non-inferiority

Primary result

As reported in the abstract

Mean difference

−0.11 cm

95% CI −0.17 to −0.1

P < 0.001

By group

CP vs PL
mean difference −0.11 cm (95% CI −0.17 to −0.1); P < 0.001

Secondary outcomes

No significant difference in percentage of glottic opening (POGO) score
P = 0.818
No significant difference in time to intubation
P = 0.55
No significant difference in intubation attempts
P = 0.99

Original publication

Non-inferiority randomized controlled trial comparing CricOid pressure and para-laryngeal pressure in parturients undergoing cesarean delivery: NiCOP trial. Int J Obstet Anesth. Published 17 April 2024. doi:10.1016/j.ijoa.2024.103997