Obstetric anesthesia

Performance of M-mode and color Doppler ultrasound for confirming epidural catheter placement in laboring women: A prospective cohort study

Anaesth Crit Care Pain MedPublished Prospective cohort study

Authors' conclusion

cD is more sensitive and faster than M-mode for EC localisation in obstetrics.

Study context

Population
Parturients requesting epidural analgesia during labour
Participants
100 participants
Exposure
M-mode vs colour Doppler ultrasound for confirming epidural catheter placement
Outcome
Feasibility of detecting the epidural catheter within the epidural space using M-mode
Methodological detailssingle-centre, observational, diagnostic accuracy
  • Single-centre
  • Observational
  • Diagnostic accuracy

Main finding

As reported in the abstract

Epidural catheter localisation by M-mode
GroupValueSensitivitySpecificityPPVNPV
M-mode48%49%100%100%4%

M-mode

Value48%
Sensitivity49%
Specificity100%
PPV100%
NPV4%

Observational data: associations, not effects.

Secondary outcomes

OutcomecDP value
Epidural catheter localisation by cDcD vs M-mode · faster detection with cD76%P = 0.001
Sensitivity78%
Specificity100%
PPV100%
NPV8%
Epidural catheter localisation by either modality
87% · sensitivity · specificity 100% · PPV 100% · NPV 13%

Epidural analgesia failure among cases undetected by either mode · 20 min post-insertion

Cases undetected by either mode
15
Epidural analgesia (EA) failed, requiring catheter repositioning
2

Original publication

Performance of M-mode and color Doppler ultrasound for confirming epidural catheter placement in laboring women: A prospective cohort study. Anaesth Crit Care Pain Med. Published 15 April 2026. doi:10.1016/j.accpm.2026.101850

Composed by AI from the published abstract and checked against it. How Briefs are made →