Hemodynamics, fluids & transfusion

Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study

Acta Anaesthesiol ScandPublished Retrospective analysis of a hemodynamic study

Authors' conclusion

Single or combined hemodynamic variables provided by esophagus Doppler monitoring and pulse oximetry derived pleth variability index could help clinicians avoid unnecessary fluid bolus infusions.

Study context

Population
Patients undergoing goal-directed fluid therapy during major open abdominal surgery266 bolus infusions
Participants
108 patients
Outcome
Fluid responsiveness (stroke volume increase ≥ 10% after bolus) by pre-infusion esophagus Doppler and pleth variability index values

Main finding

As reported in the abstract

Likelihood of fluid responsiveness by pre-infusion hemodynamics
Overall incidence of fluid responsiveness
44%
Stroke volume > 80 mL, corrected flow time > 360 ms, or pleth variability index < 10%
30%-38%
Stroke volume decreased by <8% since previous optimization
21%
Stroke volume decrease <8% combined with stroke volume > 100 mL
0%
Stroke volume ≤ 50 mL, corrected flow time ≤ 360 ms, or pleth variability index ≥ 10
50%-55%
Stroke volume decrease > 8% since previous optimization
58%
Stroke volume decrease > 8% combined with any other hemodynamic variable
66%-76%

Observational data: associations, not effects.

Original publication

Predicting fluid responsiveness using esophagus Doppler monitoring and pulse oximetry derived pleth variability index; retrospective analysis of a hemodynamic study. Acta Anaesthesiol Scand. Published 4 May 2023. doi:10.1111/aas.14260

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.