Perioperative medicine & outcomes

Preliminary Development and Validation of Automated Nociception Recognition Using Computer Vision in Perioperative Patients

AnesthesiologyPublished Prospective observational cohort study

Authors' conclusion

Automated nociception detection using computer vision alone is feasible but requires additional testing and validation given the small datasets used.

Study context

Population
Adults (≥18 yr) admitted for surgical procedures, San Francisco Veterans Affairs Medical Center; external data from University of Northern British Columbia-McMaster University and Delaware Pain Database130 development, 77 validation, 25 + 229 external
Exposure
Computer vision CNN models classifying Care Pain Observation Tool (CPOT) and NRS pain/no pain
Outcome
Binary pain/no pain classification (AUC)
Methodological detailsdiagnostic model development and validation, internal and external validation
  • Diagnostic model development and validation
  • Internal and external validation

Main finding

As reported in the abstract

Binary pain/no pain classification (AUC of ROC)
GroupAUC, development cohortAUC, San Francisco VA validation cohortAUC, University of Northern British Columbia-McMaster UniversityAUC, DelawareAUC
CPOT0.71 (95% CI, 0.70 to 0.74)0.91 (95% CI, 0.90 to 0.92)0.91 (95% CI, 0.89 to 0.93)0.80 (95% CI, 0.75 to 0.85)— not stated in the abstract
Numeric rating scale— not stated in the abstract— not stated in the abstract— not stated in the abstract— not stated in the abstract0.58 [95% CI, 0.55 to 0.61]

AUC, development cohort

CPOT0.71 (95% CI, 0.70 to 0.74)
Numeric rating scale— not stated in the abstract

AUC, San Francisco VA validation cohort

CPOT0.91 (95% CI, 0.90 to 0.92)
Numeric rating scale— not stated in the abstract

AUC, University of Northern British Columbia-McMaster University

CPOT0.91 (95% CI, 0.89 to 0.93)
Numeric rating scale— not stated in the abstract

AUC, Delaware

CPOT0.80 (95% CI, 0.75 to 0.85)
Numeric rating scale— not stated in the abstract

AUC

CPOT— not stated in the abstract
Numeric rating scale0.58 [95% CI, 0.55 to 0.61]

— not stated in the abstract

Observational data: associations, not effects.

Further findings

Calibration (Brier scores)

Brier scores improved after calibration across multiple techniques

Explainability (perturbation models, CPOT)

Eyebrows, nose, lips and forehead most important for model prediction

Original publication

Preliminary Development and Validation of Automated Nociception Recognition Using Computer Vision in Perioperative Patients. Anesthesiology. Published 13 January 2025. doi:10.1097/aln.0000000000005370

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.