Obstetric anaesthesia

Prevention of spinal anaesthesia-induced hypotension during caesarean section using noninvasive cardiac output monitoring: A randomised clinical trial

Eur J Anaesthesiol Intensive CarePublished Randomised controlled trial

Authors' conclusion

The incidence of hypotension may be reduced using estimated continuous CO monitoring, however, no differences were seen in the incidence of nausea or reactive hypertension, nor in umbilical arterial pH levels.

Study context

Population
Women undergoing elective caesarean delivery under spinal anaesthesia, Japanese hospital
Participants
200 women
Comparison
Estimated continuous CO-guided vasopressor administration vs control
  • esCCOn = 103
  • Controln = 88reference
Primary endpoint
Proportion with hypotension (SBP < 100 mmHg and/or mean BP < 65 mmHg)
Follow-up
Between spinal anaesthesia injection and delivery
Methodological detailssingle-centre, simple randomisation, Japanese hospital, 13 May 2020 to 27 April 2022
  • Single-centre
  • Simple randomisation
  • Japanese hospital, 13 May 2020 to 27 April 2022

Primary result

As reported in the abstract

P < 0.001

Secondary outcomes

Delivered phenylephrine dose

P = 0.003

Nausea and vomiting, reactive hypertension (SBP ≥ 140 mmHg), umbilical arterial blood pH

Did not differ between the groups

Original publication

Prevention of spinal anaesthesia-induced hypotension during caesarean section using noninvasive cardiac output monitoring: A randomised clinical trial. Eur J Anaesthesiol Intensive Care. Published 21 August 2025. doi:10.1097/ea9.0000000000000086

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.