Sepsis & infection

Prevention of ventilator-associated pneumonia by metal-coated endotracheal tubes: a meta-analysis

Crit CarePublished Systematic review and meta-analysis of randomised trials

Authors' conclusion

Metal-coated ETT show a lower occurrence of VAP compared to the uncoated ETT. Nevertheless, they do not considerably decrease the length of mechanical ventilation, the duration of ICU admission, nor do they reduce hospital mortality rates.

Study context

Population
Mechanically ventilated patients with endotracheal tubes (ETTs)
Participants
2,157 participants · 5 randomized controlled trials (RCTs)
Comparison
Metal-coated ETT vs uncoated ETT
Outcome
Ventilator-associated pneumonia (VAP) rate and hospital mortality
Methodological detailsDeeks funnel plot for publication bias
  • Deeks funnel plot for publication bias

Pooled result

As reported in the abstract

Metal-coated ETT vs Uncoated ETTRelative risk (95% CI)P value
VAP incidence
0.71(0.54–0.95)
P = 0.02
Mortality
1.05(0.86–1.27)
P = 0.65

Further pooled results

Mechanical ventilation duration (2 studies)

Mechanical ventilation duration, both patient groups: RR (95% CI), P, I2
RR = 0.60, 95% CI (- 0.52, 1.72), P = 0.29, I2 = 97%
No significant difference in ventilation duration between metal-coated and uncoated ETT (both studies)
  • Marked heterogeneity; pooled comparison not feasible

Intensive care unit (ICU) stay (2 studies)

ICU stay, both patient groups: RR (95% CI), P, I2
RR = 0.47, 95% CI (- 1.02, 1.95), P = 0.54, I2 = 50%

Original publication

Prevention of ventilator-associated pneumonia by metal-coated endotracheal tubes: a meta-analysis. Crit Care. Published 17 September 2024. doi:10.1186/s13054-024-05095-8

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.